PROJ-FILE-FMT=2 PROJ-DRIVER-NAME='Canon LV-7385 (Rev A)' PROJ-NAME='Canon LV-7385' PROJ-DRIVER-REV='Rev A' ; Rev Beta: based on NEC NP2000 Rev G, changed BAUD, volume, auto adjust and IR codes may not work, July 2010 BT ; Rev A: Received test unit. Replaced Volume commands with the NEC LT380 commands, added keystone, magnify, freeze from same source. -- Sept 2010 BT IR-TIME-0L=550u IR-TIME-0H=550u IR-TIME-1L=1.7m IR-TIME-1H=550u PROJ-BAUD-RATE=19200,8,N,1 IRCODE['_REPEAT']="" IRCODE['_PREFIX']="" IRCODE['_SUFFIX']="" ;power commands RSCODE['_POWER POLL']="$00,$81,$00,$00,$00,$81",REPEATS=1 RSCODE['POWER ON']="$02,$00,$00,$00,$00,$02",REPEATS=1 RSCODE['POWER OFF']="$02,$01,$00,$00,$00,$03",REPEATS=1 ;volume commands RSCODE['VOL UP']="$03,$10,$00,$00,$05,$05,$00,$01,$03,$00,$21" RSCODE['VOL DOWN']="$03,$10,$00,$00,$05,$05,$00,$01,$FD,$FF,$1A" ;selection commands RSCODE['VIDEO']="$02,$03,$00,$00,$02,$01,$06,$0E",REPEATS=1,IS-SELECTION RSCODE['S-VIDEO']="$02,$03,$00,$00,$02,$01,$0B,$13",REPEATS=1,IS-SELECTION RSCODE['COMP 1']="$02,$03,$00,$00,$02,$01,$01,$09",REPEATS=1,IS-SELECTION RSCODE['COMP 2 DIGITAL']="$02,$03,$00,$00,$02,$01,$1A,$22",REPEATS=1,IS-SELECTION RSCODE['COMP 2 ANALOG']="$02,$03,$00,$00,$02,$01,$02,$0A",REPEATS=1,IS-SELECTION ;hidden commands RSCODE['BLANK ON']="$02,$10,$00,$00,$00,$12",REPEATS=1,IS-HIDDEN RSCODE['BLANK OFF']="$02,$11,$00,$00,$00,$13",REPEATS=1,IS-HIDDEN RSCODE['SOUND MUTE ON']="$02,$12,$00,$00,$00,$14",REPEATS=1,IS-HIDDEN RSCODE['SOUND MUTE OFF']="$02,$13,$00,$00,$00,$15",REPEATS=1,IS-HIDDEN RSCODE['AUTO PC']="$02,$0F,$00,$00,$02,$05,$00,$18",REPEATS=1,IS-HIDDEN ; may not work ; Canon Remote Control RD-439E IRCODE['MENU']="D9m,d5m,%000110001001011101100010100111010",REPEATS=1,IS-HIDDEN IRCODE['SELECT']="D9m,d5m,%000110001001011111101000000101110",REPEATS=1,IS-HIDDEN IRCODE['ADJ UP']="D9m,d5m,%000110001001011101111010100001010",CONTINUE='_Intercode Long',INCLUDECONT,IS-HIDDEN IRCODE['ADJ DOWN']="D9m,d5m,%000110001001011111111010000001010",CONTINUE='_Intercode Long',INCLUDECONT,IS-HIDDEN IRCODE['ADJ LEFT']="D9m,d5m,%000110001001011110111010010001010",CONTINUE='_Intercode Short',INCLUDECONT,IS-HIDDEN IRCODE['ADJ RIGHT']="D9m,d5m,%000110001001011100111010110001010",CONTINUE='_Intercode Short',INCLUDECONT,IS-HIDDEN IRCODE['KEYSTONE UP']="D9m,d5m,%000110001001011111010001001011100",IS-HIDDEN IRCODE['KEYSTONE DN']="D9m,d5m,%000110001001011100110001110011100",IS-HIDDEN IRCODE['MAGNIFY UP']="D9m,d5m,%000110001001011110010001011011100",IS-HIDDEN IRCODE['MAGNIFY DN']="D9m,d5m,%000110001001011101010001101011100",IS-HIDDEN IRCODE['FREEZE']="D9m,d5m,%000110001001011100110010110011010",REPEATS=1,IS-HIDDEN IRCODE['_Intercode Short']="d75m" IRCODE['_Intercode Long']="d100m,d100m" RSCODE['^DELAY']="D87m",REPEATS=1 RSCODE['^DELAY2']="D986m",REPEATS=1 BYTES-TO-QUEUE=2 POWER-POLL-INTERVAL=2s POWER-POLL-TIMEOUT=500m POWER-POLL-THRESHOLD=3 POWER-POLL-STARTBYTE=6 POWER-POLL-MATCH-ANY=False POWER-POLL-MATCH-BYTES="$02" POWER-POLL-TESTBYTE-MASK=2 POWER-POLL-DURING-WARMUP=False POWER-POLL-DURING-LOCKOUT=True POWER-POLL-LOCKOUT=3s PROJ-USES-ABSOLUTE-VOL=False VOL-MUTE=0 VOL-RANGE=63 VOL-FLOOR=0 DEFAULT-LOCKOUT=1M ; projector does not appear to have mandatory cooldown period BT WARM-UP-DELAY=75s POWER-ON-DELAY=1M IO-DOWNTIME=145m IO-CANCEL-DOWNTIME-ON-RX=False USE-MODULATION-WHEN-WIRED=False INVERT-LINE-WHEN-WIRED=False CARRIER-PERIOD=25.8u CARRIER-DUTY-CYCLE=50 PROJ-MISSING-THRESHOLD=5 DEFAULT-CORE-FUNCT[REPEAT]='_REPEAT' DEFAULT-CORE-FUNCT[PREFIX]='_PREFIX' DEFAULT-CORE-FUNCT[SUFFIX]='_SUFFIX' DEFAULT-CORE-FUNCT[POLL]='_POWER POLL' DEFAULT-CORE-FUNCT[ON]='POWER ON' DEFAULT-CORE-FUNCT[OFF]='POWER OFF' DEFAULT-CORE-FUNCT[VUP]='VOL UP' DEFAULT-CORE-FUNCT[VDN]='VOL DOWN' DEFAULT-SELECTION[1]='COMP 1' DEFAULT-SELECTION[2]='COMP 2 DIGITAL' DEFAULT-SELECTION[3]='VIDEO' DEFAULT-SELECTION[4]='S-VIDEO' DEFAULT-HID-FUNCT[OFF]='MENU' DEFAULT-HID-FUNCT[VUP]='ADJ UP' DEFAULT-HID-FUNCT[VDN]='ADJ DOWN' DEFAULT-HID-FUNCT[1]='AUTO PC' DEFAULT-HID-FUNCT[2]='SELECT' DEFAULT-HID-FUNCT[3]='ADJ LEFT' DEFAULT-HID-FUNCT[4]='ADJ RIGHT' POWER-SENSE-OPTIONS=RS232Poll,None,Sensor IR-WIRING-OPTIONS=IR-Emitter PASSIVE-MODE=False